[ IQ Fire · Thermal AI ]

Catch the heatbefore the smoke.

Fixed thermal cameras watch electrical panels, motors, storage and hot-work areas around the clock. Each zone has its own temperature limit and rate of rise; alarms come in stages with a thermal snapshot, open a work order in NFFICE and stay on the equipment’s history in AI Ontology.

Problems

Sound familiar?

Each card turns over to show the answer.

01 · ProblemsSmoke detectors come late

Smoke and heat detectors react once something is already burning.

How it answers

Thermal cameras flag abnormal heat while equipment still runs — earlier warning on top of the fire alarm system you already have.

02 · ProblemsHot spots are invisible

A loose busbar joint or a dry bearing looks normal; handheld surveys come once or twice a year.

How it answers

Fixed cameras measure surface temperature around the clock, zone by zone.

03 · ProblemsEvery alarm sounds the same

One high-temperature alarm at 2 a.m. is either ignored or wakes everyone.

How it answers

Watch, warning and alarm go to different people, each with a thermal snapshot.

04 · ProblemsRepairs leave no trace

A hot spot is fixed and forgotten, and the same panel heats up again next summer.

How it answers

Each alarm opens a work order in NFFICE and lands on the equipment’s history in AI Ontology.

Features

What it does, one by one.

Each feature with a real scene and the screen behind it.

Radiometric thermal · CAM T-04
01

Thermal view

Fixed radiometric thermal cameras measure surface temperature at every point of the image, day and night, without light. They watch electrical panels, motors and bearings, storage stacks and hot-work areas. A camera needs a clear line of sight, so closed panels are watched through IR viewing windows — placed in the site survey.

Every pixel measured24/7, no light neededIR viewing windows
Motor stator · winding heat
02

Limits per zone

Each zone gets its own rules: a maximum temperature, a rate of rise, and the difference from similar parts — phase against phase, bearing against bearing. A fixed limit catches overheating; rate of rise and differences catch a fault still warming up, and ignore equipment that simply runs hot. Shiny copper is read on high-emissivity labels so values stay true.

Max temperatureRate of risePhase difference
Thermal snapshot · Panel E-3
03

Staged alarms

Watch, warning and alarm reach different people. A watch is logged on the trend; a warning goes to the on-call electrician with a thermal snapshot and a normal photo; an alarm reaches the safety lead and the control room, and can switch a relay to your fire alarm panel or PLC — wired as your fire design allows.

Watch · warning · alarmThermal snapshotRelay output
Motor terminal box · re-torque
04

Work orders in NFFICE

A warning drafts a work order in NFFICE with the snapshot, zone and temperature trend attached. The maintenance lead approves it, the technician closes it with a photo after the fix, and the camera confirms the temperature is back to normal.

Drafted from the alarmApprovalClosed with proof
Press line 3 · motor M-12
05

Equipment history

Every alarm, snapshot and repair is linked to the asset in AI Ontology — its line, load, past failures and spare parts. Maintenance sees which machines heat up again and again, and plans replacement before the hot season instead of after a failure.

Asset historyRepeat hot spotsPlanned replacement
Under the hood

From pixel to work order

Every pixel is a temperature reading. Zones, ΔT classes and alarms follow the typical values below, tuned per site.

Processing chain5 STAGES · LIVE
01Radiometric frame

An uncooled microbolometer gives a temperature for every pixel, day or night.

8–14 µm · 9–30 Hz
02Correction

Emissivity, distance and reflected temperature are set for each surface.

ε 0.95 on IR labels
03ROI analysis

Max, average and rate of rise per zone; each phase compared with the others.

Computed every 1–5 s
04Severity class

ΔT between like parts is mapped to watch, warning and alarm (NETA MTS).

ΔT 1–3 / 4–15 / >15 °C
05Alarm & work order

Snapshot to on-call staff, relay or Modbus out, work order in NFFICE.

Relay, Modbus TCP, API
Datasheet
SensorUncooled VOx, 8–14 µm

No light needed; reads surfaces, not through panel doors

Resolution384×288 or 640×512

At 3 m with a 25° lens, 640 px ≈ 2 mm per pixel

Sensitivity (NETD)< 50 mK typical

Lower NETD shows faint gradients sooner

Accuracy±2 °C or ±2 % of reading

Typical spec at 15–35 °C ambient, objects above 0 °C

Housing & powerIP66/IP67, PoE 802.3af/at

Dust- and water-jet rated; one cable for power and data

OutputsONVIF/RTSP, Modbus TCP, I/O

Relay to the fire panel only as the fire design allows

Measured targets
±2 °C / ±2 %Measurement accuracy

Compared with a reference blackbody or contact probe at commissioning.

≥ 3×3 pxMeasurement spot

Smallest target read reliably; it sets camera distance and lens.

< 10 sHeat to alert

From a zone crossing its limit to the push on the phone.

≤ 1 / cam / monthNuisance alarms

Alarms closed as no fault, after baseline tuning under normal load.

Typical targets, agreed per site in the acceptance test.

Rules that apply
VNLaw on Fire Prevention, Fighting and Rescue No. 55/2024/QH15

In force 1 Jul 2025 with Decree 105/2025/ND-CP; IQ Fire adds to the required systems.

KRAct on Fire Prevention and Safety Management

In force since 1 Dec 2022; heat logs support the fire safety manager’s checks.

JPFire Service Act (Act No. 186 of 1948)

Required automatic fire alarms stay as they are; thermal alerts add earlier warning.

EUEN 54 series (fire detection and alarm)

Fire alarm components carry EN 54; thermal cameras work beside them, not instead.

USNFPA 70B (2023) · NFPA 72

70B became a standard in 2023 and sets regular infrared checks, typically every 12 months.

Rules

You set the rules.It follows them.

Sample rules — set per site and line.

IFTerminal > 70°CINPanel E-3THENWarning + snapshot→On-call electrician
IFRise > 5°C in 2 minINWarehouse B · palletsTHENAlarm + relay output→Safety lead, control room
IFPhase difference > 10°CINMotor M-12 · press line 3THENDraft a work order→NFFICE
IFHot-work permit closedINWelding bay W-2THENWatch for hot spots after work→Fire watch
Integration

Connected to the rest of the work.

WatchesPanels, switchgear, motors, bearings, conveyors, storage, hot-work areas
CamerasFixed radiometric thermal cameras; visible camera optional
RulesPer zone: max temperature, rate of rise, difference between like parts
AlarmsWatch, warning, alarm — with thermal snapshot
OutputsApp push, relay to fire panel or PLC — agreed per site
NeedsClear line of sight; IR windows for closed panels; emissivity set per surface
IntegrationNFFICE, AI Ontology, BMS/PLC by I/O, Modbus or API
DeploymentOn-premise edge server or cloud
Thermal AIIQ Fire
NFFICE

Work orders, approvals

AI Ontology

Equipment history, causes

Fire alarm / BMS

Relay signal, per fire design

PLC / SCADA

I/O or Modbus, per site

IQ Guardian

Video check of the same area

FAQ

Questions we hear often

Does it replace smoke detectors or our fire alarm system?

No. It adds earlier warning on top of the fire prevention and fire alarm systems your site is required to have under Vietnamese law; those systems, approvals and inspections stay as they are.

Can it see inside closed panels?

Only with a clear line of sight — through IR viewing windows fitted in the panel door, or from a camera inside a large switch room. We decide this in the site survey.

What about shiny metal and false alarms?

Bare copper reflects heat, so we read it on high-emissivity labels or painted parts. Rules combine limits with rate of rise and like-for-like differences, and are tuned on a baseline under normal load.

Does it help with fire-safety compliance in Vietnam?

It keeps a record of regular checks on electrical equipment and heat sources, which supports your own fire-safety duties. How it counts under the Law on Fire Prevention, Fighting and Rescue (in force from 1 July 2025) and its decrees should be confirmed with your fire-safety consultant.

At what temperature does it alert?

You set it per zone: a maximum temperature, a rate of rise, and a difference between like parts such as phase to phase. An example rule is caution above 70°C on a panel terminal; values are tuned on a baseline under normal load.

Who gets the alert at 2 a.m.?

It depends on the level. Observe is only logged in the trend, caution goes to the on-duty electrician with thermal and visual snapshots, and alarm goes to the safety manager and the control room, with a relay signal if you want one.

Can it connect to our fire alarm panel, BMS or PLC?

Yes, through relay output, I/O or Modbus, or by API. How it is wired to the fire alarm panel is decided within what your fire-safety design allows.

Can it watch welding and other hot work?

Yes. A camera covers the welding area and keeps watching for residual heat after the hot-work permit ends, and alerts the fire watcher if a spot heats up again.

We already do a yearly thermal survey. Why fixed cameras?

A handheld survey shows one moment, once or twice a year; a fixed camera measures the same points around the clock and catches faults that heat up between surveys. The two work together: critical panels on fixed cameras, the rest in the periodic survey.

Does it work in the dark or in dusty rooms?

It measures heat, so it needs no lighting. Dust, steam or ordinary glass between the camera and the target do affect readings, so placement, lens cleaning and IR windows are planned in the survey.

See IQ Fire
on your own site.

A specialist replies within one business day — in English, Vietnamese, Japanese or Korean.

Book a consultationContact us